Culpan hotsd
χ²/N = 1.00
The whole reduced spectrum above, the region marked on it below. Shaded bands are the intervals the fit used; a tick under the axis marks a pixel the rejection mask cancelled.

| Teff [K] | 45194 ± 778 |
| log g | 6.241 ± 0.085 |
| log n(He)/n(H) | -1.774 ± 0.109 |
| reduced χ² | 0.999 over 745 points |
| radial velocity | 29.0 km s−1 |
| resolution (FWHM) | 2.00 Å |
| lines fitted | 15 |
| grids | HE-0.041.fits HE-0.125.fits HE-0.300.fits HE-0.550.fits +9 more |
| fitted | 04/09/2026 19:10:45 |
| source file | spec-102476-60592-63050394863520041.fits |
| Gaia DR3 source | 1797122038722776448 |
| parallax [mas] | 0.5971 ± 0.0463 |
| G | 15.726 |
| BP − RP | -0.377 |
| Gabs | 4.607 |
| μα [mas/yr] | 6.172 |
| μδ [mas/yr] | -6.049 |
| RUWE | 0.981 |
| l, b | 75.622, -21.434 |
| selection | f_plx |
| line | λ [Å] | shift [Å] | continuum at | ±avg | fitted over |
| Hβ | 4861.32 | 0.47 | -40.0, 40.0 | 5.0 | -45.0, 45.0 |
| Hγ | 4340.46 | 0.42 | -40.0, 36.8 | 4.5 | -43.0, 43.0 |
| Hδ | 4101.73 | 0.40 | -40.0, 31.6 | 4.2 | -43.0, 43.0 |
| Hε | 3970.07 | 0.38 | -28.0, 30.0 | 4.1 | -30.0, 35.0 |
| Hζ | 3889.05 | 0.38 | -20.0, 26.2 | 4.0 | -31.8, 32.0 |
| Hη | 3835.38 | 0.37 | -20.0, 14.6 | 4.0 | -20.7, 21.8 |
| Hθ | 3797.90 | 0.37 | -16.0, 16.0 | 3.9 | -15.6, 16.7 |
| Hι | 3770.63 | 0.36 | -13.0, 13.0 | 3.9 | -11.7, 11.6 |
| He II 4686 | 4685.70 | 0.45 | -11.9, 11.9 | 4.9 | -15.0, 13.8 |
| He II 5412 | 5411.52 | 0.52 | -15.0, 15.0 | 5.6 | -15.0, 15.0 |
| He II 4542 | 4541.59 | 0.44 | -15.0, 20.0 | 4.7 | -20.0, 20.0 |
| He II 4200 | 4199.84 | 0.41 | -23.5, 33.8 | 4.3 | -20.0, 20.0 |
| He I 4472 | 4471.60 | 0.43 | -15.0, 15.0 | 4.6 | -15.0, 15.0 |
| He I 4026 | 4026.29 | 0.39 | -24.2, 15.0 | 4.2 | -15.0, 15.0 |
| He I 4922 | 4921.93 | 0.48 | -15.0, 15.0 | 5.1 | -15.0, 15.0 |
Teff 45194 K · log g 6.241 · E(44−55) 0.080 · χ²r 0.55 over 38 bands
distance 1675 pc · parallax 0.6000 ± 0.0500 mas (8%) · R 0.1228 +0.0105 −0.0089 R☉ · M 0.960 +0.213 −0.168 M☉ — above the 0.47 canonical mass · L 56.7 +10.1 −8.1 L☉
Photometry against the model, with the residual beneath it in units of the error. The horizontal bar on each point is the passband, not an error; a hollow point was not fitted and the tooltip says why. Drag a box to zoom, double-click or Esc to come back out.